What Are the Additional Requirements on Tankers for Fire-Fighting More than 20 000 Gt

Cargo ships, with the exception of oil tankers, ≥ 10,000 GT, but 20,000 GT < New mandatory requirements for the electronic exchange of cargo, crew and passenger information have been adopted under a revised annex to the Convention on International Maritime Facilitation (ALF), which aims to harmonise the procedures for the arrival, stay and departure of ships from the port. Standard forms are revised. Expected to enter into force on 1 January 2018, under the tacit method, the normal method is to fill these tanks with inert (non-explosive) gas from the exhaust of the ship`s boiler: it is cleaned and then pumped into the empty tanks or into the remaining spaces above the oil in the loaded tanks. An inert gas system is required for all new tankers and most existing tankers of 20,000 dwt and above. IMO`s main function is to make shipping of all kinds, including oil tankers, safer. The measures contained in the many safety conventions and recommendations apply to both these and other ships – and the safer a ship is, the less likely it is to be involved in an accident. Amendments to SOLAS Regulations II-2/4.5.5 and II 2/16.3.3 stipulate that an inert gas system shall be installed on all new oil tankers and chemical tankers with a capacity of 8,000 dwt or more (when transporting cargo with a low flash point of <60 °C). Tankers of more than 20,000 dwt were already needed to install such systems. (9) For ships carrying 5 or more sets, the total free capacity of the open air is 9600 liters or if a loading device is available, the open air is 4800 liters. SOLAS Regulation II-1/3-10, introduced by IMO Resolution MSC.290(87), stipulates that oil tankers and bulk carriers (excluding ore carriers and combined vessels) with a length of 150 m (length of the loading line) and more must be accompanied by a shipbuilding record to be kept on board the ship and/or ashore* and, where appropriate, updated throughout the vessel`s service. This requirement applies to ships: the code referred to here is the Lifesaving Devices Code, which describes in detail the requirements for the release mechanism of lifeboats in the specified sections. Cargo ships <500 GT but ≥150 GT shall be equipped with BNWAS in accordance with paragraph 2.2.3 of Chapter V of SoLAS Regulation 19 no later than the time of the first assessment after 1 January 2018.

3) For tankers, two more firefighters should be kept on board. In 1992, MARPOL was amended to make it mandatory for oil tankers with a capacity of 5,000 dwt or more ordered after 6 July 1993 to equip it with a double hull or other design approved by imO (Regulation 13F (Regulation 19 of the revised Annex I, entered into force on 1 January 2007) in Annex I to MARPOL Regulation 73/78). How many fire stations or lockers are there on a ship over 4000 GRT/.? The IMDG Code is amended with respect to content, transmission, preamble, Parts 1, 2, 3, 4, 7, DF List, Appendices A and B and the index. The amendments include provisions for the carriage of charges with lithium batteries, for container charges and travel identification, for similar charging requirements and general corrections for errors. The changes will apply on a voluntary basis from 1 January 2017 and will become binding in 2018. A resolution reaffirming that an approved security management system should take into account cyber risk management in accordance with the objectives and functional requirements of the ISM Code. Administrations are encouraged to ensure that cyber risks in security management systems are adequately addressed no later than the first annual review of the company`s certificate of compliance after 1 January 2021. However, it is not mandatory.

The International Convention for the Safety of Life at Sea (SOLAS) of 1974 contains special requirements for tankers. For example, fire safety regulations for oil tankers are much stricter than for ordinary dry cargo ships, as the risk of fire on board ships carrying oil and refined products is much greater. How to calculate the capacity of the Air Botle, as U said, it should be 1200 liters and between 180-200 bar. Normally we use SCBA cylinders with 300 bar nd according to Solas the cylinder pressure should not be less than 90% of the capacity. Since 1 January 1996, all new oil tankers with a capacity of 20 000 dwt or more must be equipped with an emergency towing device at both ends of the vessel. Existing ships had to be equipped with such a system by 1 January 1999 at the latest. Tests of davits and launchers: the first sentence of paragraph 8.1.1. is replaced by the following: „For lifeboats other than free-fall lifeboats, davits and launchers, with the exception of winches, shall be subjected to a static test load equal to 2.2 times their maximum payload.” The development of the modification designs follows many years of work to prevent explosions on oil tankers and chemical tankers carrying low flash-point loads and follows the recommendations of an Inter-Industry Working Group (IIWG) set up to investigate incidents of fires and explosions on chemical and product tankers. These amendments exacerbate discharge requirements for cargo residues and tank washes in certain marine areas The exemption for existing chemical tankers with a tank volume not exceeding 3 000 m3 equipped with tank cleaning machines with a flow rate not exceeding 17.5 m3/h (per nozzle) and a combined total flow rate not exceeding 110 m3/h does not apply to chemical tankers: issued after January 1, 2016. „STCW Code” – specific training requirements for polar waters and for persons used on board passenger ships.

SOLAS Regulation II-2/10.10.4, as amended by IMO Resolution MSC.338(91), provides: „For ships built on or after 1 July 2014, at least two portable two-way radios shall be carried for each household in order to communicate with firefighters on board. These portable two-way radios must be explosion-proof or inherently safe. Ships built before 1 July 2014 shall comply with the requirements of this paragraph at the latest during the first survey after 1 July 2018. » See Class News No. 18/2014 for more instructions. Please help me clarify as follows; According to SOLAS, a total of 4 sets of firefighting equipment are needed, so 2 sets of firefighting equipment are also needed for helicopter firefighting. it was usually kept in Mid. Blind. So, is it okay, 2set in the fire lockers (one set for each fire hydrant) and 2set in the mid. store for helicopters or we need to add 2 other firefighting equipment for helicopter operation except 4set in FL. The revised MARPOL Annex I for the Prevention of Oil Pollution was adopted in October 2004 and entered into force on 1 January 2007. .